Ekinex EK-MC1-MD KNX RS485 Modbus Kommunikationsmodul

Ekinex EK-MC1-MD KNX RS485 Modbus Kommunikationsmodul

Artikel-Nr.: AR1991049
HAN: EK-MC1-MD
RS485 Modbus communication module to collect and transmit measurements data of ekinex single and three phase energy meters. Optical port for data transmission between counter and communication module. Data transmission on a RS485 line, using Modbus RTU or ASCII protocols. Change of RS485 parameters directly on the combined counter or by sending the proper Modbus protocol commands to the module. SET DEFAULT key... mehr
Preis auf Anfrage

inkl. MwSt. zzgl. Versandkosten

Lieferzeit auf Anfrage

Ekinex EK-MC1-MD KNX RS485 Modbus Kommunikationsmodul

Preis auf Anfrage

inkl. MwSt. zzgl. Versandkosten

Lieferzeit auf Anfrage

Ihre Vorteile bei uns

Ekinex EK-MC1-MD KNX RS485 Modbus Kommunikationsmodul

Artikel-Nr.: AR1991049
HAN: EK-MC1-MD
RS485 Modbus communication module to collect and transmit measurements data of ekinex single and three phase energy meters. Optical port for data transmission between counter and communication module. Data transmission on a RS485 line, using Modbus RTU or ASCII protocols. Change of RS485 parameters directly on the combined counter or by sending the proper Modbus protocol commands to the module. SET DEFAULT key... mehr
Ekinex EK-MC1-MD KNX RS485 Modbus Kommunikationsmodul
Preis auf Anfrage

inkl. MwSt. zzgl. Versandkosten

Lieferzeit auf Anfrage

RS485 Modbus communication module to collect and transmit measurements data of ekinex single and... mehr
Produktinformationen "Ekinex EK-MC1-MD KNX RS485 Modbus Kommunikationsmodul"
RS485 Modbus communication module to collect and transmit measurements data of ekinex single and three phase energy meters. Optical port for data transmission between counter and communication module. Data transmission on a RS485 line, using Modbus RTU or ASCII protocols. Change of RS485 parameters directly on the combined counter or by sending the proper Modbus protocol commands to the module. SET DEFAULT key to reset to factory default values all communication parameters. Two LEDs on the front provide information about power supply (POWER) status and communication (ACT/ERR) status. Mounting in distribution board on EN 60715 rail (1 modular unit = 18 mm).

Merkmale

RS485 side communication
* Protocol: Modbus RTU (8N1) and ASCII (7E2)
* Port: RS485
* Communication speed: 300 ÷ 115200 bps
* Termination resistor integrated in the module
Counter side communication
* Type: serial, through optical port
* Communication speed: 38400 bps
Weiterführende Links zu "Ekinex EK-MC1-MD KNX RS485 Modbus Kommunikationsmodul"
Bewertungen lesen, schreiben und diskutieren... mehr
Kundenbewertungen für "Ekinex EK-MC1-MD KNX RS485 Modbus Kommunikationsmodul"
Bewertung schreiben
Bewertungsrichtlinien: Bewertungen werden vor der Veröffentlichung auf Echtheit geprüft. Nur Bewertungen, die anhand von bewerteten Artikel und E-Mail-Adresse eindeutig einer Kundenbestellung zugeordnet werden können, werden veröffentlicht.

Die mit einem * markierten Felder sind Pflichtfelder.

Ich habe die Datenschutzbestimmungen zur Kenntnis genommen.