Device working as a gateway (protocol conversion) between a RS485 serial network with Modbus RTU protocol and a KNX (TP) network. Master function on the Modbus RTU network. Mounting in distribution board on EN 60715 rail (4 modular units, each 18 mm). To be used in KNX installations for home and building automation. Merkmale Modbus side * Electrically insulated RS485 serial communication... mehr
Preis auf Anfrage

inkl. MwSt. zzgl. Versandkosten

Lieferzeit auf Anfrage

Ekinex EK-BH1-TP-485 KNX Modbus RS485 Master - KNX Gateway

Preis auf Anfrage

inkl. MwSt. zzgl. Versandkosten

Lieferzeit auf Anfrage

Ihre Vorteile bei uns

Ekinex EK-BH1-TP-485 KNX Modbus RS485 Master - KNX Gateway

Artikel-Nr.: AR1991030
HAN: EK-BH1-TP-485
Device working as a gateway (protocol conversion) between a RS485 serial network with Modbus RTU protocol and a KNX (TP) network. Master function on the Modbus RTU network. Mounting in distribution board on EN 60715 rail (4 modular units, each 18 mm). To be used in KNX installations for home and building automation. Merkmale Modbus side * Electrically insulated RS485 serial communication... mehr
Ekinex EK-BH1-TP-485 KNX Modbus RS485 Master - KNX Gateway
Preis auf Anfrage

inkl. MwSt. zzgl. Versandkosten

Lieferzeit auf Anfrage

Device working as a gateway (protocol conversion) between a RS485 serial network with... mehr
Produktinformationen "Ekinex EK-BH1-TP-485 KNX Modbus RS485 Master - KNX Gateway"
Device working as a gateway (protocol conversion) between a RS485 serial network with Modbus RTU protocol and a KNX (TP) network. Master function on the Modbus RTU network. Mounting in distribution board on EN 60715 rail (4 modular units, each 18 mm). To be used in KNX installations for home and building automation.

Merkmale

Modbus side
* Electrically insulated RS485 serial communication port, 1-way DIP switch to activate the line terminator (120 Ohm)
* Modbus master RTU (Remote Terminal Unit) communication
* Communication speed from 1200 to 115200 baud
* Device addressing from 0 to 250
* Register exchange of Coil, Input, and Input Register Holding Register type
* Reading and writing of single and multiple registers
* Volatile support memory with "Modbus image" buffer of 1440 bytes
KNX side
* KNX TP (twisted pair) 9600 baud communication port, electrically insulated from power supply
* Volatile support memory with "image KNX" buffer of 1440 bytes
Weiterführende Links zu "Ekinex EK-BH1-TP-485 KNX Modbus RS485 Master - KNX Gateway"
Bewertungen lesen, schreiben und diskutieren... mehr
Kundenbewertungen für "Ekinex EK-BH1-TP-485 KNX Modbus RS485 Master - KNX Gateway"
Bewertung schreiben
Bewertungsrichtlinien: Bewertungen werden vor der Veröffentlichung auf Echtheit geprüft. Nur Bewertungen, die anhand von bewerteten Artikel und E-Mail-Adresse eindeutig einer Kundenbestellung zugeordnet werden können, werden veröffentlicht.

Die mit einem * markierten Felder sind Pflichtfelder.

Ich habe die Datenschutzbestimmungen zur Kenntnis genommen.