Ekinex EK-BH1-TP-TCP KNX Modbus TCP/IP Master - KNX Gateway

Ekinex EK-BH1-TP-TCP KNX Modbus TCP/IP Master - KNX Gateway

Artikel-Nr.: AR1991031
HAN: EK-BH1-TP-TCP
Device working as a gateway (protocol conversion) between an Ethernet network with Modbus RTU protocol and a KNX (TP) network. Master function on the Modbus RTU network. Mounting in distribution board on EN 60715 rail (4 modular units, each 18 mm). To be used in KNX installations for home and building automation. Merkmale Modbus side * Ethernet (IEEE 802.3) communication port, RJ45 connector, at... mehr
Preis auf Anfrage

inkl. MwSt. zzgl. Versandkosten

Lieferzeit auf Anfrage

Ekinex EK-BH1-TP-TCP KNX Modbus TCP/IP Master - KNX Gateway

Preis auf Anfrage

inkl. MwSt. zzgl. Versandkosten

Lieferzeit auf Anfrage

Ihre Vorteile bei uns

Ekinex EK-BH1-TP-TCP KNX Modbus TCP/IP Master - KNX Gateway

Artikel-Nr.: AR1991031
HAN: EK-BH1-TP-TCP
Device working as a gateway (protocol conversion) between an Ethernet network with Modbus RTU protocol and a KNX (TP) network. Master function on the Modbus RTU network. Mounting in distribution board on EN 60715 rail (4 modular units, each 18 mm). To be used in KNX installations for home and building automation. Merkmale Modbus side * Ethernet (IEEE 802.3) communication port, RJ45 connector, at... mehr
Ekinex EK-BH1-TP-TCP KNX Modbus TCP/IP Master - KNX Gateway
Preis auf Anfrage

inkl. MwSt. zzgl. Versandkosten

Lieferzeit auf Anfrage

Device working as a gateway (protocol conversion) between an Ethernet network with Modbus RTU... mehr
Produktinformationen "Ekinex EK-BH1-TP-TCP KNX Modbus TCP/IP Master - KNX Gateway"
Device working as a gateway (protocol conversion) between an Ethernet network with Modbus RTU protocol and a KNX (TP) network. Master function on the Modbus RTU network. Mounting in distribution board on EN 60715 rail (4 modular units, each 18 mm). To be used in KNX installations for home and building automation.

Merkmale

Modbus side
* Ethernet (IEEE 802.3) communication port, RJ45 connector, at least 5E cable category
* Modbus master RTU (Remote Terminal Unit) communication
* Device addressing from 0 to 250
* Register exchange of Coil, Input, and Input Register Holding Register type
* Reading and writing of single and multiple registers
* Volatile support memory with "Modbus image" buffer of 1440 bytes
KNX side
* KNX TP (twisted pair) 9600 baud communication port, electrically insulated from power supply
* Volatile support memory with "image KNX" buffer of 1440 bytes
Weiterführende Links zu "Ekinex EK-BH1-TP-TCP KNX Modbus TCP/IP Master - KNX Gateway"
Bewertungen lesen, schreiben und diskutieren... mehr
Kundenbewertungen für "Ekinex EK-BH1-TP-TCP KNX Modbus TCP/IP Master - KNX Gateway"
Bewertung schreiben
Bewertungsrichtlinien: Bewertungen werden vor der Veröffentlichung auf Echtheit geprüft. Nur Bewertungen, die anhand von bewerteten Artikel und E-Mail-Adresse eindeutig einer Kundenbestellung zugeordnet werden können, werden veröffentlicht.

Die mit einem * markierten Felder sind Pflichtfelder.

Ich habe die Datenschutzbestimmungen zur Kenntnis genommen.